American Air & Water UV Air Cleaners UV Air And Water Purification  
   
     Contact | Login
profile uv systems uv science facts press releases uv info business programs

LTC - Liquid Tank Conditioners

    UV PRODUCTS

 

 

UV Liquid Tank Conditioning Units - Description & Technical Specifications
Liquid Tank Conditioners - UV Disinfection And Filtration

LTC-2AB Liquid Tank Conditioners - UV + HEPA Filtration

» View LTC Brochure /PDF/
 

*****************************************
Note:
The LTC units were redesigned. Go to LTC UV Systems for the new models.
*****************************************

Designed to filter and disinfect air in the headspace of liquid storage tanks, the Liquid Tank Conditioning UV / filtration systems are well suited for water, liquid sugar and syrup storage applications where warm, moist conditions encourage bacteria, yeast and mold growth. Through UV disinfection and filtration these UV systems create positive pressure in the tank headspace with air 99% free of dust and microorganisms - bacteria, yeast, mold and mold spores. The LTC UV systems are mounted outside the tank, so there is no concern about broken lamps or electrical components being introduced into the stored product. Additionally the UV lamps are shatter-proof coated to further diminish the risk of broken lamps. An extensive array of options and customized solutions allows us to provide equipment that fits each customer's unique application, as well as stringent UV disinfection and filtration requirements. If our standard UV liquid tank conditioners and the available options do not fulfill your needs, we can build a unit to any specifications.

Liquid Tank Conditioners

AB Series Liquid Tank Conditioners mount on top of liquid storage tanksLiquid Tank Conditioners are constructed of high grade 304 stainless steel to mount on top of liquid storage tanks (as shown) and provide unsurpassed filtration and UV disinfection. Using two 10-micron filters, one 0.3-micron Absolute HEPA filter, a 140CFM blower motor and two UVC germicidal lamps, these conditioners will filter and sterilize air in the tank headspace. The blower continuously supplies clean, disinfected air into the tank and maintains positive pressure at all times. The LTC units can handle drop-out rates of up to 200GPM and must be mounted on top of the tank.

LTC-2AB Series Standard Features

 - All units have two 36" shatter-proof coated germicidal UV lamps GML005T
 - Two 10-micron pre-filters FLT025 and a 0.3-micron HEPA filter FLT035 (10" x 10" x 6")
 - 140 CFM blower motor
 - 304 stainless steel construction
 - Designed to mount on top of tank
 - 3" threaded PVC female coupling or 3" Tri clamp ferrule (4" Tri clamp available on request)
 - Electronic ballasts for 120V 60Hz and 220V 50Hz

Liquid Tank Vent - LTX Filtration SystemA Liquid Tank Vent LTX filtartion system should be installed on the tank exhaust to prevent contaminated air from entering if rapid product drop-out creates reverse suction through the exhaust. The AB Series LTX Vent system consists of two 10-micron (FLT025) pre-filters and one 0.3 micron Absolute HEPA (FLT035) filter housed in a high grade 304 stainless steel enclosure.

LTC-2P Series

Designed for applications that don't require the high efficiency filtration of the LTC-2AB Series, LTC-2P conditioners and vents do not include the 0.3-micron Absolute HEPA filter and have only one 10-micron filter.

LTC-2PF1A0-P0Z & LTC-2PF3A0-P0Z - single 10-micron filter, 140CFM blower, two GML005T UV lamps
LTX10P SSF - Vent - single 10-micron filter (FLT025)

Custom UV with heaterCustom Liquid Tank Conditioners

Custom designs for specific requirements available as well as customized liquid tank conditioner units. The picture shows a large SC UV tank conditioner with heat control. Larger picture shown on the SC4AB page.

Ultraviolet Sterile Conditioners Technical Data

Germicidal ultraviolet systems for liquid storage tanks (liquid sugar / syrup and water). Sterile conditioners, vents, blowers using two germicidal UV lamps, 10 micron filters and HEPA filters. All conditioner systems constructed of high grade 304 stainless steel.

Tank Conditioners
Models

Tank Conditioners Description and Dimensions

Note: The LTC units were redesigned. Go to LTC UV Systems for the new models.

Double UV lamp sterile conditioner 38" L x 20" H x 12" W for up to 200GPM drop-out rates
LTC-2PF1A0-P0Z 3" female threaded PVC Coupling, single 10-micron filter (FLT025), 140CFM blower,
120V 60Hz
LTC-2PF3A0-P0Z 3" Tri Clamp Ferrule, single 10-micron filter (FLT025), 140CFM blower,
120V 60Hz
LTC-2AB1A0-P0Z 3" Female threaded PVC Coupling, two 10-micron filters (FLT025), 0.3-micron HEPA filter (FLT035), 140CFM blower, 120V 60Hz
LTC-2AB3A0-P0Z 3" Tri Clamp Ferrule, two 10-micron filters (FLT025), 0.3-micron HEPA filter (FLT035), 140CFM blower, 120V 60Hz
LTC-2AB3AH-P2Y 3" Tri Clamp Ferrule, two 10-micron filters (FLT025), 0.3-micron HEPA filter (FLT035), 140CFM blower, 220V 50Hz, Heater
LTC-2AB3AH-P0Z 3" Tri Clamp Ferrule, two 10-micron filters (FLT025), 0.3-micron HEPA filter (FLT035), 140CFM blower, 120V 60Hz, Heater
Optional components
EL/HV TG Current sensing relay with lamp on/off indicator
AF-100 Air flow indicator - indicates clogged filters or blower motor failure
Tank vent - high grade stainless steel construction, 10" filters (one required with items shown above)
LTX10P SSF Vent - electrostatic filter FLT025
LTX10AB SSF Vent - HEPA absolute filter FLT035 and two electrostatic filters FLT025
Tank blower - high grade stainless steel construction, 10" filters
LTB10P SSF Blower - 60 CFM blower; electrostatic filter FLT025
LTB10AB SSF Blower - 100 CFM blower; HEPA FLT035 & two electrostatic filters FLT025
Replacement Parts Shatter-proof UV lamps GML005T, 10" filters: HEPA FLT035, 10-micron FLT025
Go to LTC UV Systems for the new models.

Contact American Air & Water for Pricing

Liquid Tank Conditioners ^


american-lights | utility fixtures | hvac uv lights | portable uv | water uv lights | uv accessories | uv lamps | sporicidin
 
 

© 2002 - 2021
American Air & Water®, Inc.
843-306-0070

Privacy Statement and other Policies

uv systems | uv systems | uv science facts | press releases | links and q&a | uv programs
contact | login

300Pix Web Design